Bosch DCI 700 Manual Original página 41

Common-rail injector test bench
Tabla de contenido

Publicidad

1
2
3
 25:
Opening the test tank oil cap
9. Place a collecting container
of the test oil tank.
10. Open the drain cock of the test oil tank
drain the test oil out of the test oil tank (filling ca‐
pacity = approx. 50 liters) into the collecting con‐
tainer.
— Alternative: Use an external test-oil pump to
pump the test oil out of the test oil tank and into
a collecting container.
 26:
Draining the test oil
11. Dispose of the used test oil. Comply with disposal
 25 "Substances hazardous to wa-
instructions (see
ter").
---Separator---
4.2.2.2 Flushing the test oil tank
1. Flush the empty test oil tank with test oil. Collect
the test oil emerging from the drain cock in a col‐
lecting container.
2. Clean the test oil tank with lint-free cloths.
3. Flush again until all dirt residues have been removed
from the test oil tank.
Robert Bosch GmbH
(2)
under the drain cock
(1)
and
1
2
4. Close the drain cock of the test oil tank.
 27:
Closing the drain cock
5. Dispose of the used test oil. Comply with disposal
 25 "Substances hazardous to wa-
instructions (see
ter").
---Separator---
4.2.2.3 Emptying the heat exchanger
1. Remove the lower cover
DCI 700.
1
 28:
Back of DCI 700
2. Place the end of the drain hose
release nipple into a collecting container.
DCI 700 | 41 | en
(1)
on the back of the
(2)
without a quick-
1 689 989 473 | 2020-11-24

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido