5.3 Electrical connection:

IMPORTANT: This machine must be earthed.
It is recommended that the system be protected with a fuse and an RCD.
Your mains electricity supply to the machine must be protected as indicated below:
TL40 and TL 110:
-
North America: 15 A protection;
-
Rest of the world: 16 A protection.
TL 270:
-
32 A protection.
For machines equipped with a variable speed drive, it is imperative that they be connected to a
junction box on a circuit fitted with a type B 300 mA RCD.
Note: Any problem resulting from any other type of connection will not be covered under warranty.
Before connecting your machine to the mains supply and in order to prevent the motor from burning
out when it is switched on, it is important to check that the mains supply matches the machine
specification (see machine nameplate).
This machine complies with Machinery Directive 2006/42 and is CE marked as proof of this.
Please familiarise yourself with the safety pictograms displayed on the machine:
This pictogram indicates an electrocution hazard. Please isolate the machine
before carrying out any work on it. You will find it on the electrical enclosure. (fig.
6, n°20)
You will find the circuit diagram for the machine inside the electrical enclosure
cover. (fig. 6, n°21)

5.4 Commissioning:

Before commissioning, ensure that there are no extraneous objects interfering with the
machine's moving parts.
For machine operation, please refer to the "Operation" chapter.

5.5 Danger:

If the user or the machine is in danger, you must use the main isolator switch to cut the power
supply to the machine (fig. 4, n°17).
Remove the plug from the mains socket before any maintenance and/or servicing work.
Any maintenance work or replacement of parts must be carried out by an approved agent.