6.18 Resetting
When "DEFAULT" is activated, the pump will return
to the factory settings.
Note: The calibration is also set back to the default
setting. This means that a new calibration is required
when the "DEFAULT" function has been used.
Default settings are the factory settings of standard
pumps. Select "DEFAULT" in the "SETUP" menu.
Fig. 19

6.19 Return

Fig. 20
The "RETURN" function makes it possible to return
from any level in the menu to the operating display
without changes after the menu functions have been
used.
24
Operating display
Default settings:
Operating mode:
Manual
Capacity:
Maximum capacity
Control panel lock: Unlocked
Default lock code:
2583

Anti-cavitation:

Not active
Analog signal:
4-20 mA
Digital inputs:
NO (normally open)
Capacity limitation: Maximum capacity
Alarm reset required to restart the pump
Dosing monitoring: Off

Language:

English
Units:
Metric
Operating display
without changes
6.20 Language
The display text can be displayed in one of the
following languages:
English
German
French
Italian
Spanish
Portuguese
Dutch
Swedish
Finnish
Danish
Czech
Slovak
Polish
Russian