The stove is clogged
early in the brazier with
burning irregular, door
glass gets dirty, the
flame is long, reddish
and weak
Smell of smoke in the
environment. Turning
off the stove.
In the automatic posi-
tion the stove always
runs at full power
The engine smoke ex-
traction does not work
1. Flue with presence of stretches
too long or clogged
2. Too pellet
3. Excessive pellet or ash deposits in
the brazier
4. The brazier is not found in its slot
5. Wind contrary to the exhaust
flow
6. Insufficient combustion air
7. You changed the type of pellets
used
8. Smoke extractor motor broken
9. Door closed incorrectly
1. Poor combustion
2. Malfunction of fan fumes
3. Installation of the flue per-
formed incorrectly
4. Clogged chimney
1. Room thermostat set to maxi-
mum
2. Significant temperature sensor
failure
3. Control panel defective or
broken
1. The stove has no voltage
2. The motor is broken
3. The board is defective
4. The control panel has failed
1. Perform periodic cleaning. See paragraph stove instal-
lation in the user manual. Check chimney cleaning
2. Decrease in the parameters the charge level of the
pellets
3. Clean the brazier after waiting for the total shutdown
of the stove. If you repeat contact your Authorized
Service Center
4. Check that the hole in the brazier matches the glow
plug
5. Check the chimney cap windproof and / or possibly
install it
6. Check the correct position of the brazier, its cleanli-
ness and check that the air intake in both free environ-
ment, verify the status of the door seal, increase the level
in the parameter relative to the speed of the fan exhaust
fumes. Contact your Authorized Service Center
7. Check the quality of the pellets. Contact your Au-
thorized Service Center
8. Increase the level in the parameters relating to the
speed of the fan exhaust fumes. Check and eventually
replace motor
9. Check that the glass is sealed and the seal guarantees
tightness
Contact your Authorized Service Center
1. Reset the thermostat temperature
2. Check the operation of the sensor and replace if nec-
essary
3. Check the control panel and replace if necessary
1. Check the supply voltage and the protection fuse.
2. Check the motor and capacitor and replace if neces-
sary.
3. Replace the circuit board.
4. Replace the control panel.
25