Wireless Thermostat Installation

Install the Wireless Thermostat as described in the supplied manual. In order to verify a radio
transmission path, assign the Wireless Thermostats to the according heating zone from the place
of intended installation. Perform the radio transmission test if necessary.
Fix the mounting base
Remove the tempera-
to the wall.
ture dial.
Passive interference:
Passive interference can
occur if the Basis Wireless
868 MHz is not installed
on the same floor as the
thermostats; if they are
separated by a reinforced
concrete partition with a
high steel proportion; or,
if there is an integrated
vapour lock made of alu-
minium foil in the ceiling
or a separating the wall.
868
MHz
SET
1.
2.
OPEN
Made in Germany
AR 4010KF
2x1,5V AA
SET
T
1.
2.
CLOSE
2-A40-10-500
0036
OPEN
Made in Germany
Made in Germany
Raum
Room
AR 4010KF
AR 4010KF
2x3V AA
2x3V AA
Heizzone
Heating Zone
T 1A
T 1A
CLOSE
2-A40-10-500
2-A40-10-500
0036
0036
Raum
Room
Heizzone
Heating Zone
Note the room and
the heating zone on
the inscription field.
Remedy 1:
The position of the wireless thermostats can
AR 4070 KF
be changed. It may be possible to improve
the signal of the Wireless Thermostat by
changing the thermostat installation site.
AB 4071-6
Remember:
with direct sunlight exposure, with
heating air or water are not recom-
mended.
Remedy 2:
The position of the Basis Wireless unit can-
not be changed due to the fixed position
of the heating circuit distributor. However,
the Basis unit can be optionally equipped
with an external receiver AB EX 4070. This
receiver has a 5 m (optionally 20 m) cable
and can be routed to places where all wire-
less thermostats can be received without
any troubles.
20
Radio transmission
After the assignment of the individual
wireless thermostats to the heating
zones, control operation begins. Every
controller sends its coding, the set value
1.
2.
SET
and the target value to the connection
OPEN
Made in Germany
AR 4010KF
2x1,5V AA
CLOSE
2-A40-10-500
0036
Raum
Room
Heizzone
Heating Zone
unit. The coding is necessary for the
wireless connection unit to separate the
data.
Install
the
thermo-
stat on the mounting
Function indication of the heating zones
base.
After the assignment, the heating zone indicator displays the cur-
rent switching state of the heating zone output. In most cases the
LED goes out, but may illuminate again a short time later since the
wireless connection unit starts controlling the room temperature.
The LED also lights up if the Basis unit still has not finished the rout-
ing for switching, which lasts 8 minutes (see start-up). The LED also
lights up if the Set button on the thermostat has been pressed sev-
installation
location
eral times by accident during the allocation. In this case, the wireless
connection unit starts the radio test immediately after the allocation
process, i. e. the corresponding output is switched active for 1 min-
ute, independent from the control system.
Temperature Setback Mode:
When the Temperature Setback mode is active:
from the set target value.
from the set target value (HK module necessary).
AB 4071-6 / AB 4071-12

Control Operation

24V AC
Radio transmission
DEU
ENG
FRA
ITA
SPA
NLD
RUS
DAN
NOR
SWE
FIN

Publicidad

Tabla de contenido
loading

Productos relacionados para Moehlenhoff Basis AB 4071-6

Este manual también es adecuado para:

Basis ab 4071-12

Tabla de contenido