Examples Of Correct Installation - Cadel MINI Manual De Instalación, Uso Y Manutención

Cocina de lena
Ocultar thumbs Ver también para MINI:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 99
SYSTEM TYPE
Minimum vertical length
Maximum length (with 1 union)
Maximum length (with 3 unions)
Maximum number of unions
Level section (minimum inclination 3%)
Installation at a height above 1200 m a.s.l.
• Use a specific plate pipe for stoves.
• It is forbidden to use metal, fibre cement or aluminium flexible pipes.
• For change of direction it is obligatory always to use a T-union (or a curve not with right angle) with
inspection plug which enables an easy periodic cleaning of the pipes.
• Please assure you that after the cleaning the inspection plugs are sealed with its efficient gasket.
• It is forbidden to connect more appliances to the same fume conduit.
• It is forbidden to convey in the same fume conduit exhausts from overhanging cooker hoods.
• It is forbidden to exhaust flue gases directly from the wall towards the outside and closed spaces also
at open top.
• It is forbidden to connect any other appliance (wood stoves, cooker hoods, boilers, etc...).
• The fume conduit must be placed at a distance of minimum 500 mm from flammable or heat-susceptible
components.
• The fume conduit must be connected with stove exhaust in a fixed and tight manner, and if required
with the insertion of a damper (see FEATURES page 65).
7.10

EXAMPLES OF CORRECT INSTALLATION

WOOD COOKING STOVES
Fig. 8 - Example 1
LEGEND
Fig. 8 page 43
1
Insulating material
2
Reduction from Ø150 to Ø120 mm
3
Inspection plug
4
Minimum safety distance = 0,5 mt
5
Damper
Ø150 mm PIPE
1,5 mt
6,5 mt
4,5 mt
3
2 mt
NO
Ø240 mm PIPE
2 mt
10 mt
8 mt
3
2 mt
Obligatory
43
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido