MAINTENANCE - ENTRETIEN - MANUTENCIÓN
headvalve replacement
fig. 41 - Identify the position of the headvalve in the built-in thermostatic body.
fig. 42 - Remove the components of the extension for the opening control.
fig. 43 - Remove the bush inserted by pressing.
fig. 44 - Loosen the plastic bush.
fig. 45 - Removefromthebodytheheadvalveusinga11/16"[17mm]socketspanner(notsupplied).
Replace the headvalve and re-assemble the mixer reversing the procedure.
Forproperhandleinstallationpleasereadsection:"Orientationofthehandleforflowadjustment".
substitution de la tête
fig. 41 - Identifierlapositiondelatêtedanslecorpsthermostatiqueencastrement.
fig. 42 - Enlever les composants de la rallonge pour la commande d'ouverture.
fig. 43 - Extraire la douille insérée en pressant.
fig. 44 - Dévisser la douille en plastique.
fig. 45 - Extraireducorpslatêteabîméeutilisantunecléentubede11/16"[17mm](pasfournie).
Remplacerlatêteetassemblerànouveaulemélangeurensuivantleprocédéinverse.
Pourl'installationcorrectedelapoignéeconsulterlasection:"Orientation poignée pour réglage du flux".
sustitución de la montura
fig. 41 - Individúenlaposicióndelamonturaenelcuerpodeltermostáticoporempotrar.
fig. 42 - Quiten los componentes de la alargadera para el control de la temperatura.
fig. 43 - Remuevanelbujeintroducidoporpresión.
fig. 44 - Destornillen el buque de plástico.
fig. 45 - Extraigan del cuerpo la montura dañada utilizando una llave de tubo de 11/16" [17mm] (no
incluidaenelsuministro).
Sustituyanlamonturayvuelvanaensamblarelmezcladorsegúnelprocedimientoinverso.
Parainstalarcorrectamentelamaneta,consultenlasección:"Orientación de la maneta para la regulación
delflujo".
32