MAINTENANCE - ENTRETIEN - MANUTENCIÓN
fig. 52
fig. 54
filters cleaning and/or substitution
If a small water leakage occurs check the conditions of filters positioned on the wall built-in body.
fig. 52 - Find the position of filters on the body of the thermostatic mixer.
fig. 53 - Unscrewthefilterwitha5/16"[8mm]Allenkey.
fig. 54 - Take out the filter and remove the o-ring and the net.
fig. 55 - Keep on with cleaning operations using running water to remove impurities. Verify that also the
seats were clean from impurities or limestone.Finally,followingtheoppositesequence,placefiltersin
their seats and check that all works properly.
Forproperhandleinstallationpleasereadsection:"Orientationofthehandleforflowadjustment".
Nettoyage et/ou substitution des filtres
S'il y a une petite fuite d'eau il faut vérifier les conditions des filtres positionnés sur le corps encastré
dans le mur.
fig. 52 - Identifier la position des filtres sur le corps du mitigeur thermostatique.
fig. 53 - Dévisserlefiltreavecunecléde5/16"[8mm].
fig. 54 - Extraire le filtre et enlever le filet.
fig. 53