Switching On
Turn on water supply
N
NOTICE
The machine may only be switched on
when the water intake hose is connected
and the water supply has been turned
on. Otherwise the machine may be
damaged due to lack of water.
Completely unroll the high-pressure
N
hose
Turn the master switch to I – now
N
the machine is in standby mode
Point the spray gun at the object to
N
be cleaned – never at persons!
When the machine is switched on,
voltage fluctuations that occur under
unfavorable mains conditions (high
power line impedance) may negatively
affect other connected electrical
appliances.
Trouble is not anticipated at power line
impedances less than 0.15 ohms.
RE 271, RE 271 PLUS, RE 281, RE 281 PLUS
Working
Actuate the spray gun
Direct the spray attachment towards
N
the object to be cleaned
Point the rotary nozzle downwards
N
when starting (if fitted)
1
Press the safety latch (1) in the
N
direction of the arrow – the lever (2)
is unlatched
Squeeze the lever (2)
N
The motor stops when the lever is
released.
Standby
NOTICE
The machine must not be operated in
standby mode for more than 5 minutes.
If work is interrupted for more than
5 min., during breaks or if the machine is
left unattended, switch off the machine
at the master switch – see "Switching off
the machine".
Pressure/quantity control on the
machine
Working pressure and water flow rate
can be set on the high-pressure pump
for long-term adjustment in line with the
cleaning job concerned.
4
Turn the knob (3) to set the working
N
pressure and water flow rate
The pressure in the high-pressure pump
is indicated by a pressure gauge (4).
Pressure control at the nozzle
The operating pressure can be infinitely
adjusted at the nozzle.
Turn the nozzle sleeve – the
N
quantity of water delivered remains
unchanged
English
3
43