Troubleshooting

Problem
Engine is running, but no
AC output is available.
Engine runs well at no-load
but "bogs down" when
loads are connected.
Engine will not start; starts
and runs rough or shuts
down when running.
For all other issues, see a MOSA Authorized Dealer.
Product Specifications
Starting Surge* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3,000
Running Watts** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,600
Load Current:
at 230 Volts AC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.3 Amps
at 12 Volts DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Amps
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 Hertz
Phase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Single Phase
Displacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 cc (10.44 cu. in.)
Spark Plug Gap. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.6-0.7 mm (0.023-0.027 in.)
Fuel Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.7 L (1.5 U.S. gallon)
Oil Capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.6 L (20 Ounces)
* Starting Surge represents the momentary electrical current the generator can provide to start electric motors.
Starting Surge does not represent the power required to continuously run electrical loads. Starting Surge is the maximum
current that can be supplied when starting a motor, multiplied by the generator's rated voltage.
** Generator per ISO 8528 Performance class G1 Reciprocating internal combustion engine driven alternating current generating
sets.
10
Cause
1. Red overload alarm light is on.
Generator is overloaded.
2. Green output indicator light not on.
Fault in generator.
3. Poor connection or defective cord set.
4. Connected device is bad.
1. Generator is overloaded.
1. Engine switch set to OFF (0) position.
2. Low oil level.
3. Dirty air cleaner.
4. Out of fuel.
5. Spark plug wire not connected to
spark plug.
6. Flooded with fuel.
Correction
1. Remove loads from generator.
Press RESET button on control
panel.
2. Contact authorized dealer.
3. Check and repair.
4. Connect another device that is in
good condition.
1. Remove loads from generator.
1. Set switch to ON (I) position.
2. Fill crankcase to proper level or
place generator on level surface.
3. Clean or replace air cleaner.
4. Fill fuel tank.
5. Connect wire to spark plug.
6. Wait 5 minutes and re-crank engine.