10.1. Replace flat fan nozzle
Remove flat fan nozzle
■ Pull the flat fan nozzle [2-6] off the front nozzle [2-7] of the dry jet gun.
Insert the new flat fan nozzle
■ Push the flat fan nozzle [2-6] onto the front nozzle [2-7] of the dry jet
gun until locks in place.
10.2. Replace connection nipple
Remove connection nipple
■ Unscrew connection nipple [2-5] from the air connection of the dry jet
gun [2-4].
Insert new connection nipple
■ Screw connection nipple [2-5] onto the air connection of the dry jet gun
[2-4] (torque: 1 Nm).
10.3. Replace sieve
Remove sieve
■ Take sieve [2-1] out of the filter holder [2-2].
Insert new sieve
Notice!
The sieve is symmetrical in design. It can be fitted in any direction.
■ Press sieve [2-1] into the filter holder [2-2] .
10.4. Replace filter holder
Remove filter holder
■ Pull the filter holder [2-2] off the rear nozzle [2-3] of the dry jet gun.
Insert new filter holder
■ Push the filter holder [2-2] onto the rear nozzle [2-3] of the dry jet gun.
10.5. Clean dry jet gun
Tool damage caused by incorrect cleaning
The dry jet gun can be damaged if immersed in solvent or cleaning
agent or if cleaned in an ultrasonic cleaning machine.
→ Do not place the dry jet gun in solvent or cleaning agent.
→ Do not clean the dry jet gun in an ultrasonic cleaning machine.
Attention!
Operating instructions SATA dry jet 2
EN
67