Electric agitator
MU-...E(G)1500...
Operating instructions
9. Commissioning
9.1 Drive motor
Requirements:
Compare mains conditions (voltage and frequency) with the specifications on the type plate of the motor.
Permissible voltage tolerance (DIN VDE 0530)
for rated voltage
for rated voltage range
The connecting cable must be dimensioned according characteristics of the motor.
Secure the connecting cable with a strain relief.
The nominal motor output applies to a maximum ambient temperature of 40°C and an installation site not higher than
1.000m above sea level.
The motor output will be reduced if these values are exceeded (see VDE 0530).
Suitable for "moderate" climates according to IEC 721-2-1.
INFO!
9.2 Initial commissioning / recommissioning
Checks prior to each start-up
Check whether the fastening screws of the flange have been tightened with the specified torque and, if applica-
■
ble, retighten.
Check whether all electrical connections are correct.
■
Check the rotational freedom of the mixing element.
■
10. Operation
As soon as the drive motor is supplied with power,
the mixing unit will start to operate.
INFO!
The mixing unit does not have an I/O switch.
Devices for turning on and off the mixing unit have to be installed by the operator.
52
www.sera-web.com
+ 10%
+/- 5%
The operation of the mixing unit will heat up the drive motor.
Do not touch the motor during the operation!
Subject to technical modifications!
TA 452 Rev. 4
en
03/2015