7.9.2 Selection of operating mode
Select the operating mode by means of the
mechanical contact in each module.
Operating
Left pump
mode
head
Alternating
Alternating
Standby
Alternating
Standby
Standby
Standby
Standby
Standby operation
Fig. 9
Mechanical contact
Operating the pump
Twin-head pumps can be set and operated in the
same way as single-head pumps. The duty pump
uses its setpoint setting, whether it is made on the
control panel, with the R100 or via bus.
Both pumps should be set to the same
setpoint and control mode.
Note
Different settings will result in different
operation when changing between the
two pumps.
7.10 Connection to LON network
The pump can be connected to a LON network via a
GENI module and an external Grundfos G10 LON
interface. Product number: 605726.
LON network
24 VAC/VDC
Fig. 10
Connection to LON network
Right pump
head
Alternating
Standby
Alternating
Standby
Alternating operation
GENI module
8. Setting the pump
For the setting of the pump, use:
•
control panel.
•
R100 remote control.
•
bus communication (not described in detail in
these instructions, contact Grundfos).
The table shows the application of the individual
operating units and in which section the function has
been described.
Possible settings
AUTO
ADAPT
Automatic night-time duty
Proportional-pressure
control
Constant-pressure control
Setpoint setting
Max. curve duty
Min. curve duty
Constant-curve duty
Temperature influence
Activation/deactivation of
pump buttons
Allocation of pump number
Start/stop
Resetting of fault
indications
Reading of various data
"-" = not available with this operating unit.
8.1 Factory setting
The pump is factory-set to AUTO
automatic night-time duty.
8.2.1
8.7.1
8.2.1
8.7.2
8.2.1
8.7.1
8.2.1
8.7.1
8.2.2
8.5.1
8.2.3
8.5.2
8.2.4
8.5.2
-
8.5.2
-
8.7.3
-
8.7.4
-
8.7.6
8.2.5
8.5.2
8.2.6
8.5.3
8.6.1 -
-
8.6.7
without
ADAPT
17