Technical Data For Electrical Connection - Lotus cooker E104-UPE Instrucciones Para La Instalación, Uso Y Mantenimiento

Hornos a convección
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 56
EN
1.5 POSITIONING OF THE OVEN
The place where the oven will be installed must comply the following requirements:
Be protected from atmospheric agents and have an adequate air circulation;
Comply with regulations concerning safety at work;
Have a room temperature between 5 °C and 35 °C with a humidification not higher than 70%.
Place the oven and proceed with levelling using adjustable feet.
Keep a suitable distance at the back, in order the label of equipotential clamp is easy to see when the oven has
been installed.
The same clamp must be easy to access to install equipotential cable after the oven has been installed in compli-
ance with our instructions.
Install the appliance in a position that allows access to the right side for installation, maintenance and technical
assistance.

1.6 TECHNICAL DATA FOR ELECTRICAL CONNECTION

Power loading
Model
and voltage
4 x 2/3 GN
4 x 460x340
220 - 240 V 1N ~
4 x 1/1 GN
4 x 60x40
380 - 415 V +3N~
4 x 1/1 GN
4 x 60x40
6 x 1/1 GN
6 x 60x40
380 - 415 V +3N~
6 x 1/1 GN
6 x 60x40
10 x 1/1 GN
10 x 60x40
380 - 415 V +3N~
10 x 1/1 GN
10 x 60x40
DIGITAL PROGRAMMABLE
CONVECTION + MANUAL HUMIDIFICATON
no. and motor
3.3 kW
1 x 240 W
50/60 Hz
6.5 kW
2 x 240 W
50/60 Hz
7.9 kW
2 x 240 W
50/60 Hz
11.9 kW
3 x 240 W
50/60 Hz
Heating
power
power
3.0 kW
6.0 kW
7.4 kW
11.1 kW
22
Absorbed
Feed cable
current
section
14.0 A
cable included
11.0 A
5 x 2.5 mm
13.5 A
5 x 2.5 mm
20.0 A
5 x 4.0 mm
2
2
2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

E106-upeE110-upeE604-upeE606-upeE610-upe

Tabla de contenido