The answers are listed below in summary form, for further details see the other pages of this document.
1) What do I need to prepare in order to install the boiler- replace?
Flue pipe at least 80 mm in diameter or direct connection to the outside.
An air inlet in the room that is at least 80 cm².
¾" G outlet and inlet tting.
¾" G drains connection for overpressure valve.
¾" G load tting.
A certi ed electrical connection with a thermal magnetothermic switch 230V +/- 10% 50 Hz.
(assess the division of primary and secondary circuits).
2) Can the boiler-stove work without water?
NO. Using the boiler-stove without water will damage it.
3) Does the stove generate hot air?
Yes. Most of the heat produced is transferred to the water, while a fan produces hot air to heat the room.
4) Can I connect the inlet and outlet of the boiler-stove directly to a radiator?
NO, just like other boilers, it must be connected to a collector from which the water is then distributed to the radiators.
5) Do boiler-stove also supply hot sanitary water?
It is possible to produce hot sanitary water evaluating the power of the boiler-stove and the water plant.
6) Can I discharge the smoke from the boiler-stoves along the wall?
NO, a discharge which is conform with standards (UNI 10683/2012) must reach the ridge of the roof, and in any case proper fun-
ctioning requires a vertical stroke of at least 1.5 meters; avoiding that in case of power outage or wind, a slight amount of smoke
forms in the installation environment.
7) Do I need an air inlet in the room where it is installed?
Yes, to replenish the air used by the boiler-stove for combustion; or direct connection t the outside.
8) What settings are required on the boiler-stove display?
The desired water temperature. The boiler-stove will then adjust the power accordingly to obtain or maintain this.
For small systems, a mode can be set that ignites and shuts down the boiler-stove accordingly, as the water temperature is reached.
(contact DEALER for initial start up)
9) How often do I need to clean the combustion chamber?
Before each ignition, with the thermo stove off and cold. HAVING BRUSHED OUT THE EXCHANGER PIPES and agitated the
ue pipe cleaning rod (see page 52).
10) Do I need to vacuum the pellet hopper?
Yes, at least once a month when the boiler-stove is not used for some time.
11) Can I burn other fuel apart from pellets?
NO. The boiler-stove has been designed to burn wood pellets that are 6 mm in diameter. Any other material can damage it.
12) Can I ignite the boiler-stove by sending an SMS?
Yes, if the DEALER or an electrician has installed the connection via an optional cable code 621240 to the serial port behind the
boiler-stove.