MAINTENANCE AND FILTER REPLACEMENT METHOD

Flushing the RO Membrane

The RO membrane is automatically fl ushed for 18 seconds when the device is turned on.
When the water tank is full, the RO membrane is automatically fl ushed for 10 seconds.

Filter Replacement Method

Note!
Filters and membranes are consumables. Their replacement time
depends on the quality of raw water and water consumption.
They are not covered by the warranty.
Filter Replacement procedure
1. Turn off the power supply.
2. Close the inlet water valve.
3. Remove the top cover.
4. Unplug the "old" fi lter – disconnect fi lter from quick connectors (memorise fi lter orientation).
5. Replace the fi lter – Pay attention to correct water fl ow direction!
FLOW
6. Check all connections and make sure there are no water leaks.
7. Close the top cover.
8. Open the inlet water valve and turn on the power supply.