Saf-Fro DIGISTEEL III 420 Instrucciones De Funcionamiento Y Mantenimiento página 11

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 64
It is possible to setup time of trigger push to detect change of program chain : SETUP  CPT  put value from 1 to 100  exit SETUP
Example: Create a program list from P50 to P55 (6 programs).
1)
In program P56, put different welding cycle or synergy than P55 in order to finish chain
2)
Select program P50 (First program for start of welding
3)
Start welding
4)
Each time trigger will be pushed, power source will change program until P55. When chain is finished, power source will restart to P50.
3.3.5. Automatisation
a) DIGIPULS III welding sets is very easily automated. Simply connect the J2 socket provided at the back of the set.
The wire markings are : LEVEL N1
RI shared current contact output: dry contact
Trigger input (+): to be placed on a dry contact
Trigger input (-): to be placed on a dry contact
To confirm the closing of contact ri, it is essential to position "aut off ". The delay in the closing of the contact is adjusted by the value "dep"
in the "step" sub menu of setup.
Note : By default, the mode selected is the manual mode.
The type of operation selected is shown on the RH display.
SELECTION OF THE REMOTE CONTROL AUTOMATIC MODE WITH AN ANALOGUE SIGNAL
1.
Position the switch on the power source front panel on «
2.
Press the « OK » key to select «
3.
Position the LH selector to obtain «
4.
Position the RH selector to obtain «
DIGISTEEL III / DIGIPULS III 420-520
RI current contact output: dry contact
Shared fault
» on the display.
Con FIG
» on the LH display.
Aut
» on the RH display
n1
K de J2
L de J2
Fault
T de J2
L de J2
U de J2
M de J2
».
SEt -UP
EN
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Digisteel iii 520Digipuls iii 420Digipuls iii 520

Tabla de contenido