Do not clean the door gasket. The door gasket is essential
for a good seal. Care should be taken not to rub, damage or
remove the gasket.
Do not use oven cleaners or any oven liner protective
coating materials in or around the oven.
Never keep pet birds in the kitchen. Birds are extremely
sensitive to the fumes released during an oven self-clean
cycle. Fumes may be harmful or fatal to birds. Move birds to
a well-ventilated room.
10)Safety air valve shut-off operation guidelines
1. Take out the drawer from the front of the oven.(Figure 1)
2. Stretch your fingers into the waist-shaped hole pointed
by the red arrow (Figure 2)
3. Find the switch of the safety valve (Figure 3
4. Press the switch (Figure 4
5. Gas Supply Requirements
Installation of this range must conform with local codes, or
in the absence of local codes, with national Fuel Gas
Code, ANSIZ223.1 / NFPA 54.
In Canada, installation must conform to the current natural
Gas Installation /code, CAN 1-1.1-M81 and with local codes
where applicable.
Reading
Maximum gas pressure
Appliance Regulator
Setting for outlet pressure
Safety Tips for Gas Operation
Keep appliance area clear and free from combustible
materials, gasoline, and other flammable vapors.
Do not obstruct the flow of combustion air into the range
and ventilation air away from the range.
Ventilation: Please do make sure that the unit be set under
a powered, vented exhaust hood of sufficient size and
capacity.
Before installing the range, you must locate and secure the
included anti-tip bracket to the wall for your range.
The use of cabinets for storage above the appliance may
result in a potential burn hazard. Combustible items may
ignite; metallic items may become hot and cause burns. If a
cabinet storage is to be provided, the risk can be reduced by
installing a range hood that projects horizontally a minimum
of 5" (12.7cm) beyond the bottom of the cabinets.
The appliance shall not be used for space heating. This
information is based on safety considerations.
WARNING
NEVER use this appliance as a space heater
to heat or warm the room. Doing so may
result in carbon monoxide poisoning and
overheating of the oven.
All openings in the wall behind the appliance and in the
floor under the appliance shall be sealed.
6. Dimensions and Clearances
The range may be installed flush to the rear wall.
You may install a non-combustible material, such as tile, on
the rear wall above the range and up the vent hood.
It is not necessary to install non-combustible materials
behind the range below the counter top height.
The minimum distance from the side of the range above
the counter top to combustible sidewalls must be at least
10 inches.
The depth of cabinets installed above cooking tops shoud
be less than 13 in (330mm. 30" Gas Range Clearance.
7
NG (Natural
LP in. w.c.
Gas) in. w.c.
13.0
10.0
5.0