Top Hood and cabinet specifications

Condition
Clearance between the top of the
cooking surface and the bottom of an
unprotected wood or metal cabinet.
Clearance between the top of the cooking
surface and the bottom wood
or metal cabinet that is protected by not
less than:
1/4-inch-thick flame-retardant
millboard covered with not less than:
No. 28 MSG sheet steel or
0.015-inch-thick stainless steel or
0.024-inch-thick aluminum or
0.020-inch-thick copper
� n"
!一一一一 --
1
I J
Minimum
clearance allowed
36"
24"
Maximum depth for cabinets
above coumtertops
Pront edge of the range side
panel forward from cabinet

7. Electric Power Supply Requirements

Your range must be electrically grounded in accordance
with local codes or, in the absence of local codes, in
accordance with the National Electrical Code (ANSI/NFPA
70, latest edition).
In Canada, electrical grounding must be in accordance with
the current CSA C22.1 Canadian Electrical Code Part 1
and/or local codes. A copy of this standard may be
obtained from: National Fire Protection Association, 1
Battery march Park, Quincy, Massachusetts 02269-9101.
The power supply must be the correct polarity. Reverse
polarity will result in continuous sparking of the electrodes,
even after flame ignition. If there is any doubt as to
8