INSTRUCTIONS FOR CLEANING

REMINDERS FOR CLEANING

The manufacturer will not be liable for any damage or in-
jury resulting from failure to observe the following rules
• Disconnect the appliance electric supply, if present, before
carrying out any operation.
• Clean the satin finish stainless steel exterior surfaces, the
cooking wells and the surface of the hotplates every day.
• At least twice a year, have an authorized technician clean the
internal parts of the appliance.
• Do not use direct or high pressure water jets to clean the
appliance.
• Do not use corrosive products to clean the floor beneath the
appliance.
SATIN FINISH STAINLESS STEEL SURFACES
• Clean the surfaces with a cloth or sponge using water and
proprietary non-abrasive detergents. Follow the direction of
the satin finish lines. Rinse repeatedly and dry thoroughly.
• Do not use pan scourers or other iron items.
• Do not use chemical products containing chlorine.
• Do not use sharp objects which might scratch and damage
the surfaces.
COLLECTION TRAYS
Clean the surface, removing grease, oil, food residue etc

15 GAS GRILL

Cleaning the burner and brazier grille
• Lift up and remove the cooking grille and the splashguard.
• Remove the tiles by lifting them up slightly at the back and
releasing them from the front guide pins.
• Proceed to clean the burner around the flame zone and along
the flame protector apertures, removing all traces of dust and
burnt-on residue whilst taking care not to enlarge the flame
apertures.
• Using a scraper, clean the fins of the combustion chamber
that convey cooking juices into the collection drawer and then
wipe with a damp cloth. Take care not to damage the pilot
ignition unit.
• Refit the tile, taking care to insert the front pins in their seats.

INSTRUCTIONS FOR MAINTENANCE

REMINDERS FOR THE MAINTENANCE TECHNICIAN

The manufacturer will not be liable for any damage or in-
jury resulting from failure to observe the following rules
• Read this manual carefully. It provides important information
for safe installation, use and maintenance of the appliance.
• Installation, conversion to a different type of gas and applian-
ce maintenance must be carried out by qualified technicians
authorized by the manufacturer, in compliance with current
safety standards and the instructions in this manual.
• Identify the specific appliance model. The model number is
detailed on the packaging and on the appliance data plate.
• The appliance must be installed in a well-ventilated room.
• Do not obstruct any air vents or drains present on the ap-
pliance.
• Do not tamper with appliance components.

16 CONVERSION TO A DIFFERENT TYPE OF GAS

See Chapter " Instructions for installation "

17 COMMISSIONING

Following installation, conversion to a different type of gas or
any maintenance operations, check appliance operation.In the
event of any malfunction, consult the next Paragraph "Trou-
bleshooting".

17.1 GAS APPLIANCES

Switch on the appliance as directed in the instructions and re-
minders for use given in Chapter " INSTRUCTIONS FOR USE
" and check:
• the gas supply pressure ( see next Paragraph ).
• the correct ignition of the burners and the effectiveness of the
fumes removal system.
17.1.1
CHECKING THE GAS SUPPLY PRESSURE
• To measure the gas supply pressure use a manometer with a
minimum definition of 0.1 mbar.
• Remove the control panel.
• Remove the screw from the pressure test point PP and con-
nect the manometer to the test point.
• Make the measurement with the appliance in operation.
IMPORTANT! If the gas supply pressure is not within the limits
( Min. - Max ) indicated in Table T2 , cease operation of the
appliance and contact the gas utility company.
• Disconnect the manometer and retighten the retaining screw
on the pressure connection.

18 TROUBLESHOOTING

18.1
GAS GRILL
The pilot burner does not light
Possible causes:
• Insufficient gas supply pressure.
• Blocked tubing or nozzle.
• Defective gas tap
• Igniter defective or not properly connected.
• Igniter or igniter wire defective.
Pilot burner goes out during use
Possible causes:
• Insufficient gas supply pressure.
• Defective gas tap
• Defective thermocouple or insufficient heating.
• Thermocouple incorrectly connected to gas tap.
• Knob of gas tap not pressed sufficiently.
The main burner does not light ( even though pilot is lit )
Possible causes:
• Defective burner ( gas outlet holes clogged ).

19 REPLACING COMPONENTS

REMINDERS FOR REPLACING COMPONENTS

• Disconnect the appliance electric supply, if present, before
carrying out any operation.
• After replacing a gas system component, check for gas leaks
at connection points.
• After replacing an electrical system component, check it is
correctly wired.
5