For Canadian Hazardous Installation Only
NON - HAZARDOUS LOCATION
(SAFE)
CONTROLLER
CONTROLLER
NOTE:
1) THE TRANSDUCER CABLE MUST BE TERMINATED IN AN AREA EXTERNAL
TO THE HAZARDOUS LOCATIONS, CLASS I & II GROUP A,B,C,D,E,F & G
2) A SEAL SHALL BE INSTALLED WITHIN 50mm OF THE TRANSDUCER CONDUIT HUB
FOR CLASS I, DIV. 1 HAZARDOUS LOCATIONS ONLY.
3) INSTALLATION SHALL BE DONE IN ACCORDANCE WITH CEC
PART 1 REQUIREMENTS.
SIEMENS CANADA LIMITED
SIEMENS MILLTRONICS
PROCESS INSTRUMENTS
PETERBOROUGH, ONTARIO, CANADA
See Siemens Milltronics drawing number 0-8850004Z-DI-A for current drawing
Page EN-12
XPS Series Transducers – QUICK START MANUL
CERTIFIED
CONDUIT
SIEMENS
SEAL
FITTING
CERTIFIED
CONDUIT
SIEMENS
SEAL
FITTING
Product Group
ULTRASONICS
01 / APRIL /1996
B. GRAY
S. NGUYEN
T. VU
PETERBOROUGH
FOR INTERNAL USE ONLY
00027003
HAZARDOUS LOCATION
CSA CLASS I, GROUP A,B,C,D
CSA CLASS II, GROUP E,F,G
METAL CONDUIT
JUNCTION BOX
CLASS I & II
METAL CONDUIT
COAXIAL
NON COAXIAL
REVISED TITLE BLOCK PER ECN P5A00004758
3
REMOVED MILLTRONICS REFERENCE
ADDED CLASS 1, DIV 1, HAZARDOUS LOCATIONS ONLY
2
TO NOTE 2 PER ECN 98-885-0-0011
ADDED CANADIAN INSTALLATION STATEMENT
1
PER ECN 96-000-0-M028
0
FOR CONSTRUCTION
XPS/XCT TRANSDUCER SERIES
INTERCONNECTION DIAGRAM
0-8850004Z-DI-A
1 : 1
CERTIFIED
CONDUIT
SEAL
FITTING
XPS/XCT SERIES
TRANSDUCER
CERTIFIED
CONDUIT
SEAL
FITTING
XPS/XCT SERIES
TRANSDUCER
PJF
MC
SN
RPC
BG
ALC
TV
BG
NTS
1
1
A5E32282889
JULY
03/2012
AUG
12/98
AUG
008/96
APR
01/96
A
3