Recommended Test Pressures & Acceptable Ranges - Elcometer AVU Guia Del Usuario

Unidad de verificación de adherencia
Ocultar thumbs Ver también para AVU:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
R
9 RECOMMENDED TEST PRESSURES & ACCEPTABLE RANGES
Megapascals (MPa)
Gauge
Elcometer AVU
Pressure
Acceptable Range
3.0
2.74 - 3.26
8.0
7.74 - 8.26
13.0
12.74 - 13.26
Megapascals (MPa)
Gauge
Elcometer AVU
Pressure
Acceptable Range
2.0
1.74 - 3.26
5.0
4.74 - 5.26
10.0
9.74 - 10.26
Megapascals (MPa)
Gauge
Elcometer AVU
Pressure
Acceptable Range
0.5
0.43 - 0.58
1.0
0.85 - 1.15
1.5
1.28 - 1.73
2.0
1.70 - 2.30
7
ELCOMETER 506 ANALOGUE GAUGES (Accuracy: ±1% of full scale)
Gauge
Elcometer AVU
Pressure
Acceptable Range
18.0
17.74 - 18.26
23.0
22.74 - 23.26
ELCOMETER 506 DIGITAL GAUGES (Accuracy: ±1% of full scale)
Gauge
Elcometer AVU
Pressure
Acceptable Range
15.0
14.74 - 15.26
20.0
19.74 - 20.26
25.0
24.74 - 25.26
ELCOMETER 106 SCALE 1 (Accuracy: ±15% of the reading)
Gauge
Elcometer AVU
Pressure
Acceptable Range
2.5
2.13 - 2.88
3.0
2.55 - 3.45
3.5
2.98 - 4.03
Pounds Per Square Inch (psi)
Gauge
Elcometer AVU
Pressure
Acceptable Range
500
462 - 538
1000
962 - 1038
1500
1462 - 1538
Pounds Per Square Inch (psi)
Gauge
Elcometer AVU
Pressure
Acceptable Range
500
462 - 538
1000
962 - 1038
1500
1462 - 1538
Pounds Per Square Inch (psi)
Gauge
Elcometer AVU
Pressure
Acceptable Range
100
85 - 115
200
170 - 230
300
255 - 345
Gauge
Elcometer AVU
Pressure
Acceptable Range
2000
1962 - 2038
2500
2462 - 2538
3000
2962 - 3038
Gauge
Elcometer AVU
Pressure
Acceptable Range
2000
1962 - 2038
2500
2462 - 2538
3000
2962 - 3038
Gauge
Elcometer AVU
Pressure
Acceptable Range
400
340 - 460
500
425 - 575
www.elcometer.com

Publicidad

Tabla de contenido
loading