Table of Contents:
Standards ...................................................... 2
Installation ...................................................4
Chimneys ......................................................4
Chimney Height ..................................................................5
Floor Protection .................................................................. 7
Operation......................................................8
Adding Fuel ..........................................................................9
Maintenance .............................................. 10
Glass Care ........................................................................... 10
Gaskets ................................................................................. 11
Accessories .................................................. 11
Firescreen ............................................................................ 11
Outside Air Kit .................................................................... 11
Rear Heatshield ..................................................................12
Figures .................................................... 13-14
Save these instructions and make them available to
anyone using or servicing the stove.
Safety notices:
• Be sure to read this entire manual before you install or
use your new Jøtul F 600 woodstove.
• If this room heater is not properly installed, a house
fire may result. To reduce the risk of fire, follow the
installation instructions. Failure to follow these
instructions may result in property damage, bodily
injury, or even death.
• Jøtul recommends that you have your new Jøtul F 600
installed by a professional installer of solid fuel burning
appliances.
• Extremely hot while in operation! Keep children,
clothing and furniture away. Contact may cause skin
burns.
• Avoid creating a low pressure condition in the room
where the stove is operating. Operating an exhaust
fan or a clothes dryer could create a low pressure area,
causing poisonous gases to come out of the stove into
the room.
• You can prevent low pressure conditions by providing
adequate combustion air within 24" but not closer than
12" from the stove. Or, simply install the optional outside
air manifold system, which allows the direct connection
of air from outside the house to the stove.
• Do not use chemicals or fluids to start the fire.
Some fuels will, during combustion, separate carbon
monoxide and generate it in the burn chamber. Carbon
monoxide is toxic, so please follow the guidelines in
this manual for proper operation of your Jøtul F 600.
• If you for some reason experience smoke "roll-out" from
the stove, it may activate smoke detectors if installed
in the house.
USA/cAnAdA
3