01_EN.fm Page 9 Monday, March 28, 2016 10:08 AM
support current values larger than the fuse ratings.
The fuse in the red wire must be connected to the power
source using the shortest practical length.
The Vehicular Charger Kit is only for use with a negative
ground system.
!
a u t i o n
Red Lead
Bulkhead
Black Lead
Grommet
Figure 6. Power Cable Routing Into Engine Compartment
Vehicle
Battery
Vehicle
Black
Chassis
Bulkhead
Ignition
Switch
Blue
1-AMP Fuse
Figure 7. PMLN6182
Remove the fuse from the power cable's red and
blue (ignition) wires before proceeding and tape
them to their respective fuse holders before
making any connection. DO NOT insert fuses
until all connections have been made and
carefully inspected.
Molded In- Line
Fuse Holder
Mounting
Hole
Engine
Compartment
Chassis Ground
5-AMP Fuse
Red
Grommet
Vehicular Charger Kit Interconnection
Diagram
9
Fuse
Cover
Red Lead
Terminal
To Vehicle
To Battery (+)
Lugs
Power Cable