SICK WL18-3 Manual De Operación página 4

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 33
8010585.YM42 | SICK
Subject to change without notice
Image: E
5
Sensor which it is not possible to set (WLF18-3): The sensor is set and ready for
operation.
After alignment is complete, move a non-transparent object into the path of the be‐
am. Refer to graphics C and G to check the function. If the switching output fails to
behave in accordance with graphic C, check application conditions. See section
Fault diagnosis.
Sensor with potentiometer:
WL18-3xxx0: The sensitivity is set with the potentiometer (type: 360°). Clockwise
rotation: operating reserve increased; counterclockwise rotation: operating reserve
reduced. We recommend setting the potentiometer to "Maximum." A lower opera‐
ting reserve may be necessary for depolarizing surfaces.
The sensor is adjusted and ready for operation. Refer to graphics C and G to check
the function. If the switching output fails to behave in accordance with graphic C,
check application conditions. See section Fault diagnosis.
Image: C
3
COMMISSIONING
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wlf18-3

Tabla de contenido