AT THE END OF THE WORK

1. Make sure the machine has been secured (see the section titled
2. Take the appliance to the designated place for emptying the tank.
3. carry out the procedures described in the chapter "MAINTENANCE".
4. Position the appliance on a flat surface in an enclosed place; there must be no objects near the
appliance that could either damage it, or be damaged through contact with it. If you decide to hang
the appliance on supports, make sure they are able to sustain its volume and weight.

MAINTENANCE

1. Make sure the machine has been secured (see the section titled
2. Remove the vacuum nozzle (1) from the hole in the cover (2) of the appliance turning it anti-clockwise
(Fig.1).
3. Remove the cover (2) of the vacuum tank (Fig.2), releasing the hooks (3) on the side of the tank
itself (Fig.3).
2
1
1
4. Remove the collection bag (4) from the tank (Fig.4). If necessary, change it.
N.B. : When using bags for collecting dust, made of fabric instead of paper, empty them and
clean them with a jet of air, check their condition and if necessary change them.
5. remove the fabric filter (5) from the appliance (Fig.5).
N.B.: If the surface of the filter is extremely dirty, brush the filter with a normal soft brush to clean
it thoroughly, and if necessary wash it in water.
ATTENTION: Check the condition of the cloth filter if the filter surface area is particularly clogged
or if it is damaged replace it.
6. Clean the inside of the collection tank with a damp cloth.
7. Insert the fabric filter (5) in the tank (Fig.6).
WARNING: Before inserting the fabric filter (5) in the tank, wait until it is completely dry if it was
washed.
ATTENTION: When inserting the fabric filter (5) in the tank, make sure that the gasket adheres
fully to the edge of the tank so that the vacuuming is not compromised.
4
5
4
8. Insert the collection bag (4) in the tank (Fig.7)
9. Place the cover (2) on the vacuum tank (Fig.8), using the hooks (3) on the side of the tank itself
(Fig.9).
ATTENTION: When putting on the cover (2) make sure that the nozzle (6) on is inserted correctly
into the hole on the collection bag (4) (Fig.8).
10. Disconnect the vacuum hose (6) from the cover (2) (Fig.10).
11. Clean the inside of the vacuum hose with a jet of compressed air, if necessary removing any
obstructions.
12. Disconnect the cleaning accessory.
13. Clean the inside of the vacuum chamber of the accessory with compressed air, and if necessary
remove any obstructions.
4
2
7
6
10
To dispose of the appliance, take it to a demolition centre or an authorised
collection centre.
Before scrapping the machine, it is necessary to remove and separate out the
following materials, then send them to the appropriate collection centres in
accordance with the environmental hygiene regulations currently in force:
Felt
Electric and electronic parts*
Plastic parts
Metallic parts
(*) In particular, contact your local distributor when scrapping electric and
electronic parts.
10071876-AA_UM_FV9+ B.indb 19
"SECURING THE
MACHINE").
"SECURING THE
MACHINE").
3
2
3
5
5
6
3
8
9

DISPOSAL

TROUBLESHOOTING

This chapter lists the most common problems linked with the use of the appliance. If you are unable to
resolve the problems with the information given here, please contact your nearest assistance centre.
PROBLEM
POSSIBLE CAUSE
The main switch is not activated.
There is no battery on the lower part
of the tank of the vacuum cleaner.
The battery is not charged.
The battery charger does not
charge the battery, the electronic
specifications of the battery
charger do not match the electronic
specifications of the mains supply.
The battery charger power cable is
damaged.
The vacuum hose is not connected
correctly to the collection tank.
The vacuum hose is not connected
correctly to the telescopic hose.
The accessory being used is not
connected correctly to the telescopic
hose.
The vacuum circuit is blocked
(vacuum hose; telescopic hose;
vacuum accessory).
There is a blockage in the vacuum
filters.

EC DECLARATION OF CONFORMITY

The undersigned manufacturer:
Via Invalidi del Lavoro, 1
37059 Santa Maria di Zevio (VR)
declares under its sole responsibility that the products
VACUUM CLEANERS mod. FV9 + B
comply with the requirements of the following Directives:
2006/42/CE (+2009/127/CE)
2014/35/CE
2014/30/CE
2011/65/UE
2009/125/CE
Harmonised rules applied:
EN 55014-1: 2006+A1: 2009+A2: 2011
EN 55014-2: 1997+A1: 2001+A2: 2008
EN 60335-1
EN 60335-2-69
EN 61000-3-2: 2006+A1: 2009+A2: 2009
EN 61000-3-3: 2013
EN 62233: 2008
EN 50581
EN 60312: 2013
Regulations applied:
666/2013
The person authorized to compile the technical file:
Mr. Giancarlo Ruffo
Via Invalidi del Lavoro, 1
37059 Santa Maria di Zevio (VR) - ITALY
Santa Maria di Zevio, 06/06/2017
19
SOLUTION
Place the main switch on "I".
Insert the battery in the battery
compartment on the top of the
appliance, making sure that the poles
of the battery are facing the top of the
appliance. Press the battery until the
catch clicks into position.
Charge the battery, read the chapter
"CHARGE THE BATTERY"".
Check that the technical data on the
battery charger's serial number plate
match the data of the mains supply.
Contact a specialised technician
immediately and replace it.
Connect the vacuum hose correctly to
the collection tank.
Connect the vacuum hose correctly to
the telescopic hose.
Connect the accessory correctly to the
telescopic hose.
Remove the obstruction in the
vacuum circuit.
Clear the obstruction in the vacuum
filters.
FIMAP S.p.A.