Husqvarna CR 125 2011 Manual Del Usuario página 72

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

REPLACEMENT OF COOLING FLUID
The cooling liquid replacement must be performed with cold
motor, as follows:
- remove the R.H. radiator plug;
- remove the drain screw (2) on the pump cover or the pump
cover by loosening the three screws (1);
- slope the motorbike on the right, to make the liquid come out
easily;
- let the liquid drain completely;
- reassemble the drain screw or the pump cover;
- pour the necessary quantity of liquid in the radiator (page 8);
- warm up the motor in order to eliminate any possible air bub-
ble;
- fit the motor in vertical position and check that the liquid in
the radiators must be 10 mm/0.4 in. over the radiant mas (if
not, top it up);
- screw the R.H. radiator plug.
20
WARNING*: Coolant on tires will make them
slippery and can cause an accident or injury.
Periodically check the connecting hoses (see "Periodical main-
tenance card"): this will avoid coolant leakages and consequent
engine seizure: If hoses show cracks, swelling or hardenings due
to sheats desiccation, their
replacement shall be advisable. Check the correct tightening of
the clamps.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wr 125 2011Cr 150 2011 usa

Tabla de contenido