OPERATION
DISCHARGE HOSE INSTALLATION
Use a commercially available hose. The hose connector and hose clamp
is provided with the pump.
1.Verify that the hose coupling packing is in good condition.
2.Securely tighten the hose connector to the pump discharge port.
3.Install the discharge hose to the hose connector.
Use a hose clamp to securely fasten the discharge hose to prevent
the discharge hose from disconnecting from the hose connector
under high pressure.
It is best to use a short, large-diameter hose, because that will reduce
fluid friction and improve pump output. A long or small-diameter hose
will increase fluid friction and reduce pump output.
HOSE CLAMP
DISCHARGE HOSE
(Commercially available)
22
HOSE COUPLING PACKING
HOSE COUPLER
HOSE CLAMP RING
HOSE CONNECTOR
DISCHARGE PORT