Setting the maximum current and
the network configuration
Electric shock
DANGER
Changes to the settings are not evaluated by the
device when it is switched on. There is also the risk of
receiving an electric shock.
e
Switch off the supply voltage and make sure that
the voltage is off before installation works are
performed.
e
Before the Wall Charger Connect is connected,
check which network configuration is available
on site. The Wall Charger Connect may only be
used with the network configurations listed here
in the corresponding arrangements. If you are
unsure about the network configuration, consult
a qualified electrician.
e
The fuse for the device must be switched off
while the settings are made for the network con-
figuration and maximum current.
The maximum current and the network configuration
are each set via a separate switch.
Fig. 16 Rotary and DIP switch
Rotary switch
1
DIP switch
2
Setting the maximum current
The maximum current of the Wall Charger Connect
can be limited via the rotary switch. This is installed
next to the terminals.
e
Use a small screwdriver to set the maximum
current.
Switch position
Current value
F
80
E
63
Installation and connection
Switch position
Current value
D
48
C
40
B
32
A
24
9
20
8
16
7
12
6
10
0,1,2,3,4,5
not assigned
Setting the network configuration
To set the network configuration, there are two DIP
switches next to the terminals.
e
Set the network configuration using the DIP
switches.
The following overview contains the settings of the
DIP switches and the corresponding network config-
uration.
DIP switch S21: OFF
DIP switch S22: OFF
Network configuration: 120 V single
phase
DIP switch S21: ON
DIP switch S22: OFF
19