7. TROUBLE SHOOTING
Error
Problem
0
No connection between the main card and
the display
1
The controller is adjusted on the "soft" joint
when it is a "hard" joint
2
The controller is adjusted on the "hard" joint
when the joint is "soft"
5
Bus undervoltage + Vbus below 25 V for at
least 3 s
6
Overload of the power stage of the torque
measuring circuit (higher than 10 A for at
least 600 ms)
7
The motor is not detected.
Tool not connected.
8
Overload of the power stage of torque
measuring circuit to 14.5 A during at least
10 ms.
05/2020
Action / Solution
Check that the flat jumper is well connected
Turn off the controller and turn on after 5 sec.
Check the type of joint
Turn off the controller and turn on after 5 sec.
Check the type of joint
Check that the controller is fed with 110 / 230
VAC (according to the country)
Decrease the cycle rate.
Avoid reaching the stall torque of the motor
Check the cable and the connection between
screwdriver and the controller
Decrease the cycle rate.
Avoid reaching the stall torque of the motor.
6159934960
Issue no: 06