Safety Notes; Correct Use - SICK WT100-2 Instrucciones De Operación

Ocultar thumbs Ver también para WT100-2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
2

Safety notes

3

Correct use

4
Commissioning
Read the operating instructions before commissioning.
Connection, mounting, and setting may only be performed by trained specialists.
Not a safety component in accordance with the EU Machinery Directive.
When commissioning, protect the device from moisture and contamination.
These operating instructions contain information required during the life cycle of the sensor.
The WT100-2 is an opto-electronic photoelectric proximity sensor (referred to as "sensor" in the
following) for the optical, non-contact detection of objects, animals, and persons. If the product is
used for any other purpose or modified in any way, any warranty claim against SICK AG shall
become void.
Photoelectric proximity sensor with background suppression
1
Check the application conditions: Adjust the sensing range and distance to the object or
background and the remission capability of the object according to the corresponding dia‐
gram [H] (x = sensing range, y = transition range between the set sensing range and sup‐
pression of the background as a % of the sensing range (object remission/background
remission). Remission: 6% = black, 18% = gray, 90% = white (referring to standard white as
per DIN 5033).
The minimum distance (= y) for background suppression can be determined from diagram
[H] as follows:
Example: x = 50 mm, y = 30 % => 30 % of 50 mm = 15 mm. That is, the background is
suppressed at a distance of > 65 mm from the sensor.
Photoelectric proximity sensor
Operating instructions
8017529 | SICK
1

Publicidad

Tabla de contenido
loading

Tabla de contenido