SICK WT100-2 Instrucciones De Operación página 3

Ocultar thumbs Ver también para WT100-2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
Commissioning
8017529 | SICK
2
Function reserve
100
10
Operating range
1
0
50
(1.97)
Image 1: H
2
Mount the sensor using a suitable mounting bracket (see the SICK range of accessories).
Note the sensor's maximum permissible tightening torque of < 0.5 Nm.
Note the preferred direction of the object relative to the sensor.
3
The sensors must be connected in a voltage-free state (V
graphics [B] must be observed, depending on the type of connection:
– Male connector connection: pin assignment
– Cable: core color
Image 2: B
Only apply voltage/switch on the power supply (V
have been completed. The green LED indicator lights up on the sensor.
Explanations of the connection diagram (Graphic B):
Switching output Q (according to Graphic B):
WT100-2P (PNP: load -> M)
WT100-2N (NPN: load -> L+)
L = light switching
D = dark-switching
4
Align the sensor with the object. Select the position so that the red emitted light beam hits
the center of the object. You must ensure that the optical opening (front screen) of the sen‐
sor is completely clear [E]. We recommend making the adjustments using an object with a
low remission.
white 90 %/90 % remission
gray 18 %/90 % remission
black 6 %/90 % remission
100
(3.94)
Distance in mm (inch)
150
(5.91)
= 0 V). The information in the
S
> 0 V) once all electrical connections
S

Publicidad

Tabla de contenido
loading

Tabla de contenido