Commissioning
Image 3: E
5
Sensor with potentiometer:
The sensing range is adjusted with the potentiometer (type: 270°). Clockwise rotation: sen‐
sing range increased; counterclockwise rotation: sensing range reduced. We recommend
placing the switching state in the object, e.g., see Graphic F. Once the sensing range has
been adjusted, the object is removed from the path of the beam, which causes the back‐
ground to be suppressed and the switching output to change (see Graphic C).
The sensor is adjusted and ready for operation. Refer to Graphics C and G to check the func‐
tion. If the switching output fails to behave in accordance with Graphic C, check application
conditions. See section Fault diagnosis.