22 English
Additional functions (Option)
Sliding clutch
EN
Always assume a safe standing position and
hold the power tool securely in both hands.
If the drill becomes wedged unexpectedly, the
power tool will suddenly jerk.
If the tool insert becomes caught
or is jammed, the drive to the drill
spindle is interrupted.
Remove the load from the machine
immediately by retracting the drill bit
Switch off the power tool and
loosen the drilling tool if the power
tool has jammed.
If the machine is switched on while
the drilling tool is jammed, high reac-
tion moments can occur.
ASL Auto-Spindle Lock
If the On/Off switch VI is not pressed,
the drill spindle and thus the tool
holding fixture are locked.
This enables screws to be driven in even when the
battery is flat and allows you to use the power tool
as a screwdriver.
Run-on brake
When the On/Off switch VI is
released, the chuck is braked, pre-
venting the inserted tool from running
on.
When driving in screws, do not release the On/Off
switch VI until the screw has been driven in flush
with the surface material. This prevents the head
of the screw penetrating into the material.
QuiXS quick change system
For quick chuck changing, when
using a QuiXS adapter or for driving
in screws without a chuck.
The bit can be inserted directly into the hexagon-
shaped socket 2 of the drill spindle 1, making the
machine shorter and lighter.
Akkuschrauber-EN / 1006
Battery
-NOTE-
The battery is supplied partially charged.
Completely charge the battery before using
your power tool for the first time.
Battery with lithium-ion technology
Total discharge protection
The "Electronic discharge protection function"
protects the LI battery against total discharge.
Should the battery discharge, the power tool is
switched off by a protective circuit. The power
tool stops operating.
-WARNING-
Do not continue to press the On/Off switch
after an automatic shutdown of the power tool.
The battery could be damaged.
Temperature-dependent overload protection
The LI battery is equipped with NTC temperature
monitoring which only permits charging within a
temperature range of 5 °C - 45 °C. This ensures
long battery service life.
Battery care
Never charge batteries at temperatures lower
than 5°C or higher than 45°C.
Never charge batteries in an environment with
high air humidity or a high ambient temperature.
If the batteries are not used for a prolonged peri-
od, store them partially charged in a cool place.
IMPORTANT! Batteries will also self-discharge
while the equipment is not in use. Charge the bat-
teries regularly to prevent this.
Or even better: Insert the battery into the charger
while it is plugged into the mains and ready for op-
eration, as the charger switches to trickle charge
when the charging process is completed. This is
the best course of action with regard to the service
life of the battery and in order to keep it fully oper-
ational.
Do not leave the battery in the charger when the
charger is not ready for operation.
Charge the battery regularly to ensure maximum
service life. This is especially important if you no-
tice that the device is no longer functioning at full
power.
Operation