4-3. Adjusting each function
The following section describes the operation of the switches for the OPERATION MODE, TEMPERA-
TURE SETTING, FAN SPEED, AIR DIRECTION SETTING, HORIZONTAL BLOW, VENTILATION
SETTING and EXTERNAL TIMER SETTINGS.
If your air conditioner is not equipped with FAN SPEED, AIR DIRECTION SETTING, HORIZONTAL
BLOW, VENTILATION SETTING and EXTERNAL TIMER SETTINGS or a PROGRAM TIMER (sold
separately), the "NOT AVAILABLE" indicator will blink when the switches for these functions are
operated and the operation will not be performed.
However, "NOT AVAILABLE" does not appear on the COLLECTIVE OPERATION SETTING
SCREEN.
If "CENTRALLY CONTROLLED" blinks when the each switch is operated, the message indicates
that the operation is prohibited by the master controller.
All of the blinking items in the COLLECTIVE OPERATION SETTING SCREEN indicate items that
can be adjusted. After the items are adjusted they will stop blinking but will remain lit and those
adjustments will be applied to all groups.
(1) Operation mode
1 Press the
• The operation mode will switch between Cool (
<Heat (
)> whenever the
enclosed in parenthesis (< >) will not be displayed if the indoor units registered in the various
groups are not equipped with these modes.
(2) Temperature adjustment
1 Press either of the
• The temperature setting will be amended by 1 °C when either of the
ture setting switch are pressed. The setting will change by 1 °C in a continuous stream if
pressure is kept on these switches.
• The room temperature can be set within the following ranges.
Cool/Dry operations:
Heat operations:
Auto operations:
• The room temperature cannot be set for Fan operations.
• Although the temperature range can be set between 19 to 30 °C regardless of the operation
mode on the collective operation setting screen, the actual temperature setting will be based on
the operation mode for each group.
(3) Fan speed adjustment
1 Press the
• The fan speed settings will differ depending on the type of indoor unit.
Fan speed
2-stage
4-stage
The fan speed will change whenever the fan speed switch is pressed.
10
operation mode switch.
or
temperature setting switch.
fan speed switch.
Remote controller display
Low
Medium 2
) → Dry (
operation mode switch is pressed. The operation modes
19 °C to 30 °C
17 °C to 28 °C
19 °C to 28 °C
Medium 1
High
) → Fan (
) → <Auto (
or
)> →
tempera-