Instructions for Use

PUMP OIl REPlACEMENT NECESSARY WARNING

FVCD 270 has a high performance vacuum pump, oil recirculation lubricated with a special lubricant
studied for this application.
With use of the machine, the oil undergoes deterioration due to suction of impurities and liquids.
Consequently, so as not to compromise appliance performance, the oil must be changed every 2500
cycles, corresponding to about 150 hours of functioning.
FVCD 270 indicates when the oil must be changed.
The oil must only be changed by an authorised dealer.
On machine switch-on, reaching the limit of 2500 cycles for the first time, all of the control panel lu-
minous indicators will flash for 3 seconds and an acoustic signal can be heard (long beep).
This visual and acoustic signal informs that the pump oil must be replaced.
Any cycle can be activated in the presence of an alarm. The alarm is zeroed with the
first oil replacement intervention.

INSUFFICIENT VACUUM SIGNAl

FVCD 270 has a device that detects the level of vacuum reached inside the chamber and which is
determinant for the correct functioning of the appliance. If a minimum vacuum level is not reached,
the cycle is automatically interrupted after about one minute. The appliance indicates the anomaly
using the luminous indicator of the
panied by an intermittent acoustic signal.
The signal re-enters on the activation of a new cycle. If the cause is not removed, the alarm situation
described is repeated.
If an insufficient vacuum is signalled, before calling the Dealer or the authorised after-sales centre,
check the correct closure of the lid and the correct insertion if the gasket in the seat.
If, after the controls suggested, the anoma-
lous situation remains, call the Dealer or
authorised after-sales, communicating the
information on the plate data.
ATTenTIon! Do not try to repair or
modify any part of the appliance:
as well as making the warrant null
and void, it can be potentially dangerous.
Entrust specialised technicians only.