Enclosure rating
5)
Protection class
Circuit protection
Ambient operating temperature
1)
16 VDC to 30 VDC, without load
2)
10 VDC to 16 VDC, without load
3)
Signal transit time with resistive load in switching mode. Deviating values possible in COM2 mode.
4)
With a light/dark ratio of 1:1 in switching mode. Deviating values possible in IO-Link mode.
5)
Pursuant to EN 60529
6)
Replaces IP69 K pursuant to ISO 20653: 2013-03
7)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
Do not bend cables below 0°C.
8)
11.1
Dimensional drawings
8020356.19RH / 15.01.2021 | SICK
Subject to change without notice
48.1
24.6
(0.97)
Ø 5.2
(0.2)
3
1
2
40
10
(0.39)
44.2
4
12.9
(0.51)
6.4
38.8
(0.25)
53.3
Figure 8: Dimensional drawing 1, cable
Center of optical axis, sender
1
Center of optical axis, receiver
2
Fixing hole Ø 5.2 mm
3
connection
4
Display and setting elements
5
WLD26P
see table
x4, xH, x5, xI: IP66, IP67, IP69
x9, xB: IP65
III
A, B, C, D
7)
–40 °C ... +60 °C
(1.89)
5
1
2
(1.57)
(1.74)
3
7.1
(0.28)
10.8
(0.43)
M12
25
(0.98)
8.1
(0.32)
(1.53)
(2.1)
Figure 9: Dimensional drawing 2, male con‐
nector
TECHNICAL DATA
1:
6)
8)
48.1
(1.89)
24.6
(0.97)
Ø 5.2
(0.2)
5
3
63.9
(2.52)
40
19.7
(1.57)
(0.78)
44.2
(1.74)
3
4
25
(0.98)
6.3
39
(0.25)
(1.54)
53.3
(2.1)
11
7.1
(0.28)
10.8
(0.43)
8.1
(0.32)
11