Installation And Assembly - Dea LIVI Serie Instrucciones De Uso Y Advertencias

Ocultar thumbs Ver también para LIVI Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 83

4 INSTALLATION AND ASSEMBLY

4.1 For a satisfactory installation of the product is important to:
• Ensure that the facility complies with current regulations and then define the full project of the automatic opening;
• Ensure that throughout the course of the gate, while opening and closing, there are no friction points;
• Ensure that there is no danger of derailment and that there are not risks that it goes out of the guides;
• Make sure the gate is in equilibrium: it must not move if it stays in any position;
• Ensure that the mounting area of the motor allows the release and a manual operation easier and safer;
• Ensure that the mounting positions of the various devices are protected from impacts and the surfaces are sufficiently robust;
• Do not allow the automation parts are immersed in water or other liquids.
4.2 Defined and satisfied these prerequisites, proceed to the assembly:
If the support surface is already available, the gear motor must be directly secured to the surface using the supplied support base,
securing it to the ground with, for example, expansion or chemical dowels.
Alternatively, foundation base ART. 460 (not supplied) must be used as follows:
• Dig a hole suited to the type of ground using the quotas indicated in Fig. 3 as a reference;
• Prepare a suitably number of raceways for electrical wires;
The raceways prepared for electrical wires must be long enough to protrude inside the motor casing (Fig. 13) and must divide unit
and motor (A) power wires from the encoder and various connected accessory wires (B), to ensure correct wire insulation.
• Position the foundation base;
• Cast the concrete and, before its starts to harden, move the foundation plate to the quotas indicated in Fig. 4 being careful that it is
parallel to the door and perfectly level. Wait until the concrete fully hardens;
• Secure the adjustable support base as illustrated. Next position the gear motor on the base and secure it with the 3 screws supplied
in Fig. 5 (apply the protection caps to the heads of the M10 screws).
If the rack is already installed, place the LIVI pinion 1-2 mm away to prevent the weight of the door from resting on the gear motor.
To do this, adjust the height of the LIVI using the adjustable support base (FIG. 5) and then firmly tighten the lock nuts.
Alternatively, proceed as follows:
• Release the gear motor and fully open the door;
• Rest the first part of the rack on the door being careful that the beginning of the rack matches the beginning of the door. Secure the
rack to the door with adequate means maintaining a 1-2 mm gap from the pinion (Fig. 6);
• Cut off the excess part of the rack;
• Lastly, manually move the door various times and make sure the alignment and 1-2 mm distance between the rack and pinion is met
for the entire length;
4.3 How to unlock the operator
Once you open the lock on the handle (protected by a plastic cover), the lever must be turned in the direction shown in Fig 7, at this
point the operator is unlocked and the gate, in the absence of other obstacles is free in his movements. The reverse process, turn the
lever until it stops and closing of the lock (remember to protect the lock with the proper cover), keeps LIVI in working condition.
4.4 Limit-switches
Adjustment of the limit-switches
Some LIVI models provides a limit-switch whose intervention must be adjusted for each installation. DEA System provides two limit
switches cams (Fig. 8) that are installed on the rack of the gate and subsequently regulated in such a way as to ensure the functionality
and safety distances in opening and closing of the gate.
Keep in mind that when the limit switches trigger, the door will move to another 2-3 cm, and it's therefore suggested to fix the end of
stroke brackets at a sufficient distance from the mechanical stops.
Adjustment of the magnetic limit switch
Attach the mounting brackets to the magnets as shown in Figure 10, making sure to mount the LIGHT BLUE magnet at the closing limit
switch, the GREEN magnet at the end of the opening limit switch (Fig. 11). Connect the cable of the magnetic sensor which is colored
BROWN at the FCC 1 input (Closing Limit Switch 1) and the BLACK one at FCA 1 input (Opening Limit Switch 1) (Fig. 12);
WARNING Refer to control board instructions to correctly identify the limit switch inputs.
WARNING Incorrect installation of the magnets can be dangerous to people or things; observe the conditions prescribed in these
instructions.
Mount the magnetic sensor as shown in Fig. 9. The sensor must protrude from the bracket for supporting at least 30mm, in this way will
avoid any interference.
Adjust the magnets support brackets so as to maintain a distance from the sensor between 10 and 20mm;
WARNING Opening and closing magnets positions are referred to a standard installation (operator placed on the left of the gate). In
case of use of the parameter P063 (NET control boards only) for an inverted installation (operator on the right), the position of the
magnets must not be changed.
23

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido