Control Panel Interface

The Control Panel Interface is located under the lid of the
enclosure. Before attempting to lift the lid of the
enclosure, verify that both left and right side locks are
unlocked. To remove the front cover, lift the cover straight
up to disengage the side hooks, then tilt and lift it away
from the unit.
When closing the unit, verify that both left and right side
locks are securely locked.
NOTE: All appropriate panels must be in place during
any operation of the generator. This includes operation
by
a
servicing
technician
troubleshooting procedures.

Using the Auto/Off/Manual Interface

Button
Selecting this button activates fully automatic system operation. It also allows the unit to automatically
AUTO
start and exercise the generator according to the exercise timer (see the Setting the Exercise Timer
section).
OFF
This button shuts down the engine and also prevents automatic operation of the unit.
This button will crank and start the generator. Transfer to standby power will not occur unless there is a
MANUAL
utility failure.
NOTE: Damage caused by mis-wiring of the interconnect wires is not warrantable.

Interface Menu Displays

The LCD display

Feature
The default page which will be displayed if no buttons are pressed for 60 seconds. This page normally
shows the current Status message and the current date and time. The highest priority active Alarm/
HOME page
Warning will be automatically posted on this page as well as flashing the backlight when such a condi-
tion is detected. In the case of multiple Alarms/Warnings, only the first message will be displayed. To
clear an Alarm or Warning, press the OFF button and then press the ENTER key.
Normally off. If the operator presses any button, the backlight will automatically light and remain on for
Display Backlight
30 seconds.
Allows the operator to navigate to all other pages or sub-menus by using the Arrows and Enter but-
tons. This page can be accessed at any time with several presses of the dedicated Escape button.
MAIN MENU page
Each press of the Escape button takes the operator to the previous menu until the MAIN MENU dis-
plays. This page contains information for - History; Status; Edit; Debug.

Menu System Navigation

See
Figure
3-5: Navigation Menu. To get to the navigation menu, use the "Escape" button from any page. It may
require pressing it several times before getting to the MENU page. Navigate to the desired menu by using the
buttons. When the desired menu is displayed and flashing, press the "Enter" button.
Owner's Manual for 60 Hz Synergy Generator™
while
conducting
Description of Operation
Figure 3-4. Generator Control Panel
Description
Operation
000425
/