Optional Equipment; Safety Precautions; General Safety Precautions; Installation Guide For Qualified Personnel - Jøtul GF 3 CF Instrucciones Para Instalación

Ocultar thumbs Ver también para GF 3 CF:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ENGLISH
Fuel:
Gas
Gas-coal set:
Natural Gas G20/ G 25, LPG G31
Gas - log set:
Natural Gas G20/G25, LPG G 30/G31
Presetting:
The appliance is prepared from the
factory for Natural Gas G20.
Gas consumption:
Natural Gas G 20: approx. 0,52 m
at full capacity. Natural Gas G 25:
approx. 0,55 m
approx. 0,34 kg/hr at full capacity
LPG G 30 (5,7 kW) approx. 0,41 kg/hr
at full capacity.
Input effect kW:
Natural Gas G 20: Approx. 3 - 6,5 kW,
Natural Gas G 25: Approx. 3 - 6,0 kW,
LPG G 31: Approx. 3,2 - 5,5 kW.
(Coals only).
LPG G 30/31: ca. 3,8 - 5,7 kW.
(Logs only).
Efficiency:
Min. 70%
Orifices:
Main burner
Gas
Labelled
G20
200
G 25
200
G31 (coals only)
140
G30/31 (logs only)
130

Optional equipment

• Floor plates in blue-black enamel. Size: 632x772x17mm.
• Remote control

Safety precautions

If leaving the appliance unattended for any time, always
turn the main control knob to the pilot only or off position.
Warning! If you detect an odour of gas:
• Do not light the stove or any other appliance.
• Do not use electrical switches or the telephone.
• Contact the fire department immediately from a
neighbour's telephone.
• This appliance does not normally require extra fixed
ventilation to be installed, but must be fitted to a
correctly functioning flue system in a sufficiently
ventilated space. This is to provide correct air suppply
for combustion and proper operation of the flue.

General safety precautions

• The appliance must only be installed and repaired by
qualified personnel.
• If there is a fault with the appliance affecting operation
or ignition, it must only be rectified by qualified
personnel. Do not use the appliance whilst a fault is
suspected and NEVER attempt Do It Yourself repairs, it
can cause serious damage and danger.
• Always turn off the gas supply before service.
• The appliance must be inspected following installation
14
All manuals and user guides at all-guides.com
/hr
3
3
/h. LPG G 31 (4,8 kW):
Pilot burner
Labelled
51
51
30
30
and inspected and serviced at least once a year by
qualified personnel.
• The appliance must only use gas of the correct type
and pressure See technical data for more details.
• The appliance is pre-set for natural gas G20. If natural
gas G25 or LPG is to be used, the fireplace must to be
converted with a conversion kit.
This is only to be installed by qualified personnel.
• It is permitted to install the appliance against a wall
made of combustible material with the clearances
specified in fig. 1- A
• The appliance must only be installed indoors.
• The minimum clearance to combustible material directly
in front of the appliance is 600 mm.
• Never store combustible gas or liquid in the same room
with the appliance.
• The air regulator on the burner tube must only be
adjusted by qualified personnel.
• If any parts of the appliance have been submerged in
water, contact qualified service personnel to replace
these parts.
• Never light the appliance without the front glass in place
or if the glass is cracked.
• Do not burn solid fuel in the appliance.
• Do not place combustible material on or near the
appliance, as the fireplace becomes hot.
• Be aware that the appliance becomes hot and make
sure to keep children and animals at a safe distance.
Installation guide for
qualified personnel
Important: The appliance is factory pre-set for Natural Gas
G20. If natural Gas G25 or LPG are to be used, the fireplace
must be converted with the conversion kit. The installation
instruction is included with the conversion kit.
Note:
• Fill in and place the label "A" at the back of the delayed
ignition door (at the back of the product).
• Fill in and place the label "B" at the assigned spot on the
approval label (above the valve bracket).
Firewall requirements
The appliance may be placed directly against a wall made
of combustible material with the clearances specified in
fig. 1 . Make sure there is adequate space for the vent
system behind the appliance and for the full height/length
of the pipe. Pipe sections of the vent system can not be
closer to combustible material than 25mm for a vertical
pipe and 50mm for a horizontal pipe.

Publicidad