Regulating The Pilot Flame; Annual Service; Electrical Connections; Operating Instructions - Jøtul GF 3 CF Instrucciones Para Instalación

Ocultar thumbs Ver también para GF 3 CF:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Regulating the pilot flame

The pilot flame should have three flames as shown in fig. 4.
The thermocouple tip should be surrounded by flames (as
shown in the figure). The flames should be stable and the
colour mainly blue. If you detect a deviation from this, turn
off the pilot flame and call for service.

Annual service

Annual service of the stove includes the following check
points.
• Lighting the pilot flame
• Cleaning the glass.
• The gasket around the glass must be inspected annually
for wear and replaced if necessary.
• Check the gas pressure if other gas equipment is
connected to the gas supply.
• Look for signs of corrosion on the firebox and the vent
system.
• Look for obstructions in the vent system (such as bird's
nests, or branches from bushes and trees).
• Test the operation of the flue system with a smoke
test.

Electrical connections

Fig. 5 illustrates how the product's wires are connected.
The table below gives a description of the position numbers
in the diagram. Note that if the product is to be operated
by a remote control, the motor (G) must be connected to
the valve (F). The batterybox (H) must be connected to the
motor, using a wire provided, and fastened back on the
heatshield. Contact your dealer for delivery and fitting of
this equipment if required.
Description of parts for the schematic diagram (fig.5)
A
Thermocouple
B
Snapstat
C
El-wire to the snapstat
D
El-interupter
E
Thermostat
F
Valve
G
El-motor (Option)
H
Battery Box (Option)
I
Remote Control (Option)
Required gas pressure:
Gas type
Right testpoint (A)
Inlet pressure
Nat.Gas G 20
20 mbar
Nat.Gas G 25
25 mbar
LPG G 31 (coals only)
30/37 mbar
LPG G30/G31 (logs only)
30/37 mbar
All manuals and user guides at all-guides.com

Operating instructions

Lighting
Note! Odours when using the stove:
When used for the first time, the fireplace may emit an
irritating gas that may smell a little. The gas is not toxic,
but the room should be thoroughly aired out for a few
hours.
During first-time use, it may take a little while before the
gas tube is cleared of air, but subsequently the appliance
should function as described in the lighting instruction.
The appliance operates with the aid of a pilot flame, which
is lit manually according to the lighting instructions.
Prior to lighting: Check the area around the appliance for
possible gas leaks/odors. Especially check near the floor,
since LPG is heavier than air and would gather close to the
floor in the event of a leakage. (Note: Natural gas is lighter
than air and will gather under the ceiling). If you detect an
odour of gas, see warning under: Safety precautions.
Only use your hands to operate the control knobs; do not
use tools. If you are unable to turn or push in the control
knob, do not use force. Call for service.
Do not use the fireplace if any part of it has been submerged
in water. Call for service to replace the parts that have
been in water.

Lighting instructions

Lighting the pilot flame (fig. 2)
• The control knobs are located on the right side of the
• Make sure the gas valve on the pipeline to the appliance
• Turn knob (1), slightly to the left towards the ignition
• Press the knob down and keep it there for five seconds.
• If the pilot does not light, continue turning to the right
• Keep the knob pressed down for ten seconds after the
• When lit, release the knob and turn further to the left
Left Testpoint (B) Hot
Set by adjustment
High
14,5 mbar
18,0 mbar
17,4 mbar
23,0 mbar
appliance.
is open. Verify that the control knob (2) for gas volume is
in position (max)
position, until it stops.
Then turn to the left to activate the piezo.
and left again to activate, until the pilot flames can be
seen down on the left side of the fire box.
pilot is lit.
to the "ON" position.
Left Testpoint (B) Cold
Set by adjustment
Low
High
3,6 mbar
13,6 mbar
3,6 mbar
17,0 mbar
8,9 mbar
16,3 mbar
8,9 mbar
21,9 mbar
ENGLISH
Low
3,1 mbar
3,1 mbar
8,4 mbar
8,4 mbar
17