Option Kits and Accessories
7 OPTION KITS AND ACCESSORIES
7.1 OPTION KITS
Some models cannot incorporate all available option kits. Refer to
a detailed description of the option kits that are available for each inverter model.
7.1.1 Dynamic Braking IGBT (only for frame size E and 500...600 V models of
frame size D) - CFW701E...DB...
Refer to
item 3.2.3.2 Dynamic Braking (standard built-in for frame sizes A, B, C and D and
optional built-in for frame size E - CFW701...DB...) on page
Dynamic Braking.
7.1.2 Nema1 Protection Degree (only for frame sizes A, B, C and E and
500...600 V models of frame size D) - CFW701...N1...
Inverter with Nema1 enclosure. Refer to
KN1X-02 kit (refer to
section 7.2 ACCESSORIES on page
7.1.3 IP55 Protection Degree (only for frame sizes B and C) - CFW701...N12...
Inverter with IP55 enclosure. Refer to
PCSC-03 kit (refer to
section 7.2 ACCESSORIES on page
7.1.4 IP21 Protection Degree (only for frame sizes A, B and C) - CFW701...21...
Inverter with IP21 enclosure. Refer to
KIP21X-01 kit (refer to
section 7.2 ACCESSORIES on page
7.1.5 STO Function - CFW701...Y1...
The STO function complies with the requirements of category 3 (PL d) according to EN ISO
13849-1, SIL CL 2 according to IEC 61800-5-2 / IEC 62061 / IEC 61508 and can be used in
applications up to category 3 (PL d) according to EN ISO 13849-1 and SIL 2 according to IEC
62061 / IEC 61508. Refer to the guide or the CD ROM supplied with the product for more
information.
NOTE!
It is not possible to assemble the top cover on inverters of frame size A that
have optional safety stop. Thus, it is not possible to raise the protection level
of these inverters to IP21 or Nema1.
STO function is incompatible with fire mode and bypass functionalities.
7.1.6 24 Vdc External Control Power Supply - CFW701...W1...
The use of this option kit is recommended with communication networks (Profibus, DeviceNet,
etc.), since the control circuit and the network communication interface are kept active (with
power supply and responding to the network communication commands) even in the event of
main power supply interruption.
Inverters with this option have a built-in DC/DC converter with a 24 Vdc input that provides
36 | CFW701
15, for more details about the
Figure B.2 on page
37).
Figure A.10 on page
146. These inverters have the
37).
Figure A.9 on page
145. These inverters have the
37).
Table 2.2 on page 6
169. These inverters have the
for