MAINTENANCE PUMP CARE
5. Reassemble all pump components with care:
a. Align the two arrows on the impeller assembly. Before
inserting the impeller, gently press the magnet against the
flange to be sure that the flange bushing is fully in its seat.
b. Replace seal ring.
6. Re-attach the pump unit to the canister using the 4 fixing
screws with a Phillips screw-driver (cross headed). While
re-assembling the pump, the 4 fixing screws should be gently
screwed until pump motor cover and canister are securely
attached. Note: Do not over tighten housing to canister.
IMPORTANT:
Be sure that impeller bearing (bushing
and O-Ring) is correctly placed at the bottom of the
impeller well. Though the bushing is made of very
resistant material, it is prone to wearing in certain
conditions. For this reason, it is recommended that you
replace it whenever the impeller unit is replaced. Follow
the instructions provided with the replacement parts
package. For any details, please refer to the Maintenance
Frequency Chart at the beginning of this instruction
manual.
IMPORTANT:
Be sure that the seal ring does not slip
between the impeller flange and the motor and that the
impeller bearing (bushing and O-Ring) is correctly placed
at the bottom of the impeller well.
7. Reassemble, reconnect, and restart the unit.
b
a
EN-23