6
Settings
Basic settings
Control modes
DIP2/5−7
9
(local mode)
10
(terminals 0)
12
(terminals 2)
14
(terminals 11)
16
(terminals 16)
40
(MCI)
44
All manuals and user guides at all-guides.com
Description
W
(DIx
High)
The technology application is controlled locally via elements on the controller
and the digital input terminals:
}
At mains connection the motor starts up automatically if RFR is bridged
or set!
DI1
Setpoint of P2 (speed)
DI2
Fixed setpoint 2
DI3
Activate DC injection brake
DI4
Change of direction of rotation (not possible if DIP1/2 = on (set to the
left))
DI5
Release holding brake manually (operating mode after setting C02580)
The technology application is controlled via the digital input terminals of the
controller:
DI1
Fixed setpoint 1
DI2
Fixed setpoint 2
DI3
Activate DC injection brake
DI4
Change of direction of rotation
DI5
Release holding brake manually (operating mode after setting C02580)
The technology application is controlled via the digital input terminals of the
controller:
DI1
Fixed setpoint 1
DI2
Fixed setpoint 2
DI3
Quick stop
DI4
Change of direction of rotation
DI5
Release holding brake manually (operating mode after setting C02580)
The technology application is controlled via the digital input terminals of the
controller:
DI1
Change of direction of rotation
DI2
Activate DC injection brake
DI3
Motor potentiometer: speed higher
DI4
Motor potentiometer: speed lower
DI5
Release holding brake manually (operating mode after setting C02580)
The technology application is controlled via the digital input terminals of the
controller:
DI1
Fixed setpoint 1
DI2
Fixed setpoint 2
DI3
CW rotation/quick stop
DI4
CCW rotation/quick stop
DI5
Release holding brake manually (operating mode after setting C02580)
The technology application is controlled via fieldbus communication.
Depending on the Communication Unit available
Fixed setpoint 3
Fixed setpoint 3
Fixed setpoint 3
Fixed setpoint 3
l