the automatic reclosing is not available, the gate is semiautomatic.
t.PAU the reclosing is available, the standstill time is set from 0 to 999.
If the function is t.PAU, the display shows 10.0: set the wished time pressing the UP or DOWN keys.
IMPORTANT: If the automatic reclosing is not available, is necessary to enable the start command in
pause(menu St.PA)

PEDESTRIAN START IN OPENING

This menu permits to select the functions of the command of
START P. during the opening phase.
PAUS the command PEDESTRIAN START stops the gate and
goes in pause.
no
the command PEDESTRIAN START is not available.
ChiU
the command PEDESTRIAN START closes the gate.

THE PHOTOCELL IN PAUSE

This menu permits to determine the functioning of two
photocells during the pause phase.
rPAU
the interruption of the photocell's ray causes
the top of the pause time; when the
photocells work again, the pause time restart
from zero.
t.PCh the interruption of the photocell's ray causes
the top of the pause time; when the
photocells work again, the gate stops for a
time to be set between 0 to 120 sec.
If the function is t.PCh, the display shows 5.0: set the
wished functions pressing the UP or DOWN keys.

AUTOMATIC CLOSING

Permits the selection between the semiautomatic or
automatic functioning. By the semiautomatic
functioning the command of START or PEDESTRIAN
START opens the gate, when the opening is complete
the gate remains still until the successive command
of opening, which will reclose it. On the other hand, it
stops automatically and remains in pause phase for
the set time (t.PAU), then it closes again through the
set closing time.
22

COURTESY LIGHTS

Thanks to the connection "courtesy
light" the PD1 control unit enables
the connection of the courtesy
lights (I.E. garden lights), which can
work automatically (lights on for the
whole cycle) or timed (lights on for a
time adjustable from 0 to 999
seconds).