The following coded error messages can occur when operating
the level V engines V2403-CR-TE4B-KRC-1 (MC 130 plus, MC
130 classic).
When an error is indicated while the engine is running, the indi-
cator lamp flashes and an error code may also be shown on the
display.
NCD error
Indicator lamp blinks
U0076
1Hz (one second interval) + on for 5 seconds +
1 Hz (one second interval) + on for 5 seconds ...
P0102
1Hz + on for 5 seconds + 1 Hz + on for 5 sec-
onds ...
Malfunction
U0076
P0102
P03014 / P1A28
P3015
P2455
Emergency operation hydraulic valve
Manual pump
1
Ball tap - normal operation
2
(A) - (E) 8mm screws
(F) Knurled screw
1. Remove the cover, then unlock the cover screws (3x) by turn-
ing to the left.
Note
A pipe is required for operating the manual pump and this is lo-
cated at the side behind the driver's seat.
An 8mm ring spanner to actuate the screws is included.
Coded error messages
Cause
No communication with exhaust gas recir-
culation
Air mass sensor not normal
Fault in the DPF system
No DPF function
Differential pressure sensor not normal
PCD Error
Indicator lamp blinks
P3014
1 Hz (1 second interval)
P1A28
1 Hz (1 second interval)
P3015
1 Hz (1 second interval)
P2455
1 Hz (1 second interval)
Remedy
Engine loses power and the exhaust emission perfor-
mance becomes worse
a Contact Customer Service
Engine loses power and the exhaust emission perfor-
mance becomes worse
a Contact Customer Service
Engine loses power and the exhaust emission perfor-
mance becomes worse
a Contact Customer Service
Engine loses power and the exhaust emission perfor-
mance becomes worse
a Contact Customer Service
No change in behaviour
a Contact Customer Service
Raise the waste container/attachment frame
1. Unscrew the screws (B, E, F).
2. Actuate the manual pump (1).
Waste container/attachment frame raises.
3. Slowly screw in screw (F).
Waste container/attachment frame lowers.
4. Screw in the bolts.
Original position is restored.
Raising the front power lift/suction mouth
1. Unscrew the screws (A, D, F).
2. Actuate the manual pump (1).
Front power lift/suction mouth raises.
3. Slowly screw in screw (F).
Front power lift/suction mouth lowers.
4. Screw in the bolts.
Original position is restored.
Releasing the parking brake spring actuator
1. Move the ball tap (2) to the horizontal position.
2. Unscrew screw (C).
3. Actuate the manual pump (1).
Spring actuator releases.
4. Move the ball tap to the vertical position.
5. Screw in screw (C).
Spring actuator is actuated (original position).
English