masking refer to Figure 8. To replace the lens, begin by sliding
one side of the lens into the clips on the pan and tilt module.
After one side is secure, do the same for the opposite side
ensuring the lens is the correct orientation with the smooth side
facing in and the two rows of circles to the bottom.
Always replace the lens the correct way up to ensure exact
beam pattern coverage as shown in Figure 8.
Table 2 below summarizes typical alignment and masking
configurations.
Table 2: Beam alignment & masking configuration
Configuration
Height (m)
Multibeam, optimum
3
Pet immunity [1]
1.5
[1] Black area should be masked for pet alley applications up to 15
meters.
Figure 9 shows the pattern for the maximum range in the
optimum position.
Selectable options
Figure 10 shows the DIL switch position (1).
Pulse count
Pulse count is the number of times the detector must detect
a presence before signalling an alarm.
Switch 2 OFF = Pulse count 2
Switch 2 ON = Pulse count 1 (most sensitive)
Detection LED
Switch 1 ON = LED Enabled
Switch 1 OFF = LED Disabled
Walk test & settling time
Allow 3 minutes for the electronics to settle when power is
applied before commencing the walk test.
To enable the LED to carry out a walk test turn Switch 1 to ON.
The detection LED lights each time the Mini PIR detects your
presence.
After walk test is complete turn Switch 1 to OFF if the LED
indication is not required.
Note:
When you conduct a walk test, make sure that the front
cover is in place. Do not conduct walk tests with the cover
removed.
The range of the detector increases without the protective front
cover. Therefore the front cover must be fitted to establish the
correct beam pattern. Pan and tilt the lens module over the
field of view to obtain the correct coverage area.
Specifications
14° to 70° detection angle,
Coverage
15 m x 13 m coverage max.
90° pan, 45° tilt
Adjustment
Fresnel lens
20 zones for each detection element, which
can be masked with the curtain sliders
4 / 22
Tilt (°)
Max. range (m)
5
15
−2
15
Customised optics
Double silicon shielded quad element
eliminates 50,000 Lux of white light
LED
Red: detector alarm
Outputs
Silent, solid state, magnetically immune
NC
Volt free relay, signal contact 24 VAC/DC at
50 mA with an integral 25 Ω series resistor.
Alarm time 5 seconds
Power input
9 to 15 VDC
Current
5.5 mA (12 V nominal)
Pulse count
1 or 2
Temperature
Analogue (thermistor) and digital sensitivity
compensation
adjustment
Control
Digital microprocessor with non-volatile
memory
Walk test
Output test mode with LED indication. Option
to disable LED
−30° to +65°C
Operating temperature
Housing
High impact ABS plastic with HDPE cover,
UV stabilised
Dimensions W x H x D
70 mm x 120 mm x 95 mm
Weight
221 g Net, 321 g Gross
Mounting height
Variable up to 6 m.
Optimum height 3 m for full range
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
Carrier Fire & Security Americas Corporation Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR
and disclaimers
SALE TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. CARRIER FIRE &
SECURITY CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY
BUYING ITS PRODUCTS, INCLUDING ANY
"AUTHORIZED DEALER" OR "AUTHORIZED
RESELLER", IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL
FIRE AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code.
Certification
This product meets the requirements of EMC
EN
Testing to the following standards:
EN 50130-4:2011
EN 61000-6-3:2007
This product meets the environmental
requirements of EN50130-5.
Electrical Safety
This product meets the requirements of Low
Voltage Directive (LVD): 2006/95/EC
Harmonised Standards:
EN 60950-1:2006+A12:2011
EN 60950-22:2006+A11:2008
Environmental
IP65
class
P/N 466-5589-ML • REV D • ISS 26MAR21