Electrical Data
Power cord may include a current interrupter device. A test and reset button is provided on the plug
case. The device should be tested on a periodic basis by first pressing the TEST button and then the
RESET button. If the TEST button does not trip or if the RESET button will not stay engaged,
discontinue use of the air conditioner and contact a qualified service technician.
Damaged power supply cord must be replaced with a new power supply cord obtained from the product
manufacture and not repaired.
Use Wall Receptacle
Standard 125V, 3-wire grounding
receptacle rated 15A, 125V AC
Standard 250V, 3-wire grounding
receptacle rated 15A, 250V AC
Standard 250V, 3-wire grounding
receptacle rated 20A, 250V AC
NOTE : Aluminum house wiring may pose special problems. Consult a qualified electrician.
ELECTRICAL SAFETY
IMPORTANT GROUNDING INSTRUCTIONS
Air conditioner has a three-prong grounding plug on
its power supply cord, which must be plugged into
properly grounded three-prong wall receptacle for
your protection against possible shock hazard.
USE OF EXTENSION CORDS
Power Supply
Because of potential safety hazards, we
strongly discourage the use of an extension
cord. However, if you wish to use an extension
cord, use a CSA certified/UL-listed 3-wire
(grounding) extension cord, rated 15A, 125V.
Use 15 AMP. time
delay fuse or 15 AMP.
All wiring should be made in accordance
circuit breaker.
with local electrical codes and regulations.
Use 20 AMP. time
delay fuse or 20 AMP.
circuit breaker.
230, 208, and 230/208 VOLT UNITS
These units are equipped with a three-prong
grounding plug on the power supply cord, which
must be plugged into a matching properly grounded
three-prong wall receptacle for your protection
against possible shock hazard. If such an outlet is
not present, one must be installed by a qualified
electrician in accordance with the National Electrical
Code and local codes and ordinances.
NOTE: DO NOT USE AN EXTENSION CORD ON
230, 208, AND 230/208 VOLT UNITS.