Step 3: (Gas Dryer ONLY)
Connect Gas Supply Pipe
For further assistance, refer to Section on Gas Requirements.
1. Make certain dryer is equipped for use with the type
of gas in laundry room. Dryer is equipped at the
factory for Natural Gas with a 3/8" NPT gas
connection.
2. Remove the shipping cap from the gas connection at
the rear of the dryer. Make sure you do not damage
the pipe threads when removing the cap.
NEW
STAINLESS STEEL
FLEXIBLE
CONNECTOR
USE ONLY
IF ALLOWED
BY LOCAL
CODES
(Use
Design A.G.A.
Certified
Connector)
3/8" NPT
GAS CONNECTION
BLACK IRON PIPE
Shorter than 20' (6.1 m) - use 3/8" pipe
Longer than 20' (6.1 m) - use 1/2" pipe
10
3. Connect to gas supply pipe.
4. Tighten all connections securely. Turn on gas and
check all pipe connections (internal & external) for
gas leaks with a non-corrosive leak detection fluid.
5. For L.P. (Propane) gas connection, refer to Section on
Gas Requirements.
1/8" NPT
PIPE PLUG
(For checking
inlet gas pressure)
EQUIPMENT
SHUT-OFF
VALVE
Install within
6' (1.8 m) of dryer
D233IE3D
505048