Malfunction
SensorLight without power
SensorLight will not switch ON
SensorLight will not switch OFF
Basic brightness does not go out
at about midnight as desired
SensorLight will not switch OFF
completely
Bulb (low-energy lamp) flickers
SensorLight will not switch ON
Change in SensorLight reach
LED flashes rapidly
Functional Warranty
This STEINEL product has been manufactured with
great care, tested for proper operation and safety in
accordance with applicable regulations and then sub-
jected to random sample inspection. STEINEL guar-
antees that it is in perfect condition and proper work-
ing order. The warranty period is 36 months, starting
on the date of sale to the consumer. We will remedy
defects caused by material flaws or manufacturing
faults. The warranty will be met by repair or replace-
ment at our own discretion. The warranty shall not
cover damage to wear parts, damage or defects
caused by improper treatment or maintenance. Fur-
ther consequential damage to other objects shall be
excluded.
Cause
Fuse faulty, not switched on,
break in wiring
Short circuit
Twilight setting set to night-time
mode during daytime operation
Bulb faulty
Power switch OFF
Fuse faulty
Detection zone not properly tar-
geted
Internal electrical fuse has been
activated (LED flashes rapidly)
Continuous movement in the
detection zone
Sensor unit not properly
engaged
External light source (e.g. other
motion detector or light) inacti-
vating the SensorLight
Basic brightness selected
Basic brightness selected
Wind is moving trees and bush-
es in the detection zone
Cars in the street are being
detected
Sudden temperature changes
due to weather (wind, rain,
snow) or air expelled from fans,
open windows
Differing ambient temperatures
Internal fuse activated
The warranty will only be honoured if the product is
sent to the appropriate Service Centre fully assem-
bled and well packed with a brief description of the
fault, receipt or invoice (date of purchase and dealer's
stamp).
Repair Service:
Our Customer Service Department
will repair faults not covered by war-
ranty or after the warranty period.
Please send the product well packed
to your nearest Service Centre.
- 14 -
Remedy
Fit new fuse; switch ON mains
switch; check wiring with volt-
age tester
Check connections
Re-adjust (control
Change bulb
Switch ON
New fuse, check connection if
necessary
Re-adjust
Switch SensorLight OFF and
back ON again after 5 sec.
Check detection zone and
re-adjust if necessary
Lightly press sensor unit to clip
it into place
Shade SensorLight from
extraneous light, observe
SensorLight for several days
as it takes some time to return
to the correct value
Turn programme selector dial to
1 (filament bulb) o.
4 (low-energy bulb)
Turn programme selector dial to
4 (low-energy lamp)
Change detection zone
Change detection zone
Change detection zone,
change site of installation
Use shrouds to define detection
zone precisely
Switch SensorLight off and
back on again after 5 sec.
36
)